Our Services
- Position:
- Home Page >
- About Us >
- Our Services
· Fire-retardant of Building Materials and components
1 | ISO 11925-2: 2010 | Reaction to fire tests - Ignitability of products subjected to direct impingement of flame - Part 2: Single-flame source test |
2 | ISO 1716: 2018 | Reaction to fire tests for building materials and products -Determination of the heat of combustion |
3 | ISO 5660-1:2015 | Reaction to fire tests-Heat release, smoke production and mass loss rate-Part 1: Heat release rate(Cone calorimeter method) |
4 | ISO 10047: 1993 | Textiles-Burning behaviour- Determination of surface burning time of fabrics |
5 | ISO 12468-1:2013 | External exposure of roofs to fire - Part 1: Test method |
6 | ISO 4589-2:2017 | Plastics-Determination of burning behaviour by oxygen index-Part 2: Ambient- temperature test |
7 | ISO 4589-3:2017 | Plastics-Determination of burning behaviour by oxygen index-Part 3: Elevated- temperature test |
8 | ISO 9772:2012 | Cellular plastic- Determination of horizontal burning characteristics of small speciments subjected to a small flame |
9 | ISO 9705:2016 | Fire tests Full-scale room test for surface products |
10 | ISO 6925: 1982 | Textile floor coverings- Burning behavior-Tablet test at ambient temperature |
11 | ISO 9239-1: 2010 | Reaction to fire tests for floorings-Part 1: Determination of the burning behavior using a radiant heat source |
12 | ISO 871:2006 | Plastics-Determination of ignition temperature using a hot-air furnace |
13 | IEC 60695-11-10: 2013 | Fire hazard testing-Part 11-10:Test flames-50W horizontal and vertical flame test methods |
14 | IEC 60332-1-2: 2015 | Tests on electric and optical fibre cables under fire conditions-Part 1-2: Test for vertical flame propagation for a single insulated wire or cables-Procedure for 1kw pre-mixed flame |
15 | IEC 60332-1-3:2015 | Tests on electric and optical fibre cables under fire conditions-Part 1-3: Test for vertical flame propagation for a single insulated wire or cables- Procedure for determination of flaming droplets/particles |
16 | ASTM E 119 - 16a | Standard Test Methods for Fire Tests of Building Construction and Materials |
17 | UL 94 -2016 | Test for Flammability of Plastic Materials for parts in devices and appliances |
18 | NFPA 285-2019 | Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Wall Assemblies Containing Combustible Components |
19 | AS 5113:2016 | Fire propagation testing and classification of external walls of buildings |
20 | EN 13823:2010 | Reaction to fire tests for building products-Building products excluding floorings exposed to the thermal attack by a single burning item |
21 | ENV 1187:2002 | Test methods for external fire exposure to roofs; German version |
22 | DIN EN 1634-1:2014 | Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware-Part1: Fire resistance tests for doors, shutters and openable windows |