Our Services
- Position:
- Home Page >
- About Us >
- Our Services
· Building curtain wall product
1 | ASTM E283-04(Reapproved 2012) | Standard Test method for determining rate of air leakage through exterior windows, curtain walls, and doors under specified pressure differences across the specimen |
2 | ASTM E331-00(Reapproved 2016) | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference |
3 | ASTM E547-00(Reapproved 2016) | Standard test method for water penetration of exterior windows, skylights, doors, and curtain walls by cyclic static air pressure difference |
4 | ASTM E330/E330M-14 | Standard test method for structural performance of exterior windows, doors, skylights and curtain walls by uniform static air pressure difference |
5 | ASTM E1233/E1233M-14 | Standard test method for structural performance of exterior windows, doors, skylights, and curtain walls by cyclic air pressure differential |
6 | AAMA 501.1-05 | Standard test method for water penetration of windows, curtain walls and doors using dynamic pressure |
7 | AAMA 501.4-09 | Recommended static test method for evaluating curtain wall and storefront systems subjected to seismic and wind induced inter-story drifts |
8 | AAMA 501.5-07 | Test method for thermal cycling of exterior walls |
9 | AAMA 501.7-11 | Recommended static test method for evaluating windows, window wall, curtain wall and storefront systems subjected to vertical inter-story movements |
10 | BS EN 13830:2003 | Curtain walling-product standard |
11 | BS EN 12152:2002 | Curtain walling-Air permeability-performance requirements and classification |
12 | BS EN 12153:2000 | Curtain walling-Air permeability-Test method |
13 | BS EN 12154:2000 | Curtain walling- Watertightness-performance requirements and classification |
14 | BS EN 12155:2000 | Curtain walling- Watertightness-laboratory test under static pressure |
15 | BS EN 13050:2011 | Curtain walling- Watertightness-laboratory test under dynamic condition of air pressure and water spray |
16 | BS EN 13116:2001 | Curtain walling-Resistance to wind load-Performance requirements |
17 | BS EN 12179:2000 | Curtain walling-Resistance to wind load-Test method |
18 | BS EN 14019:2004 | Curtain walling-Impact resistance-performance requirements |
19 | BS EN 12600:2002 | Glass in building-Pendulum test-Impact test method and classification for flat glass |
20 | BS EN 13049:2003 | Windows. soft and heavy body impact. test method, safety requirements and classification |
21 | BS EN 356:2000 | Glass in building-Security glazing-Testing and classification of resistance against manual attack |
22 | LPS 1175:ISSUE 7 | Requirements and testing procedures for the LPCB approval and listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers |
23 | CWCT | Standard for systemised building envelopes |
24 | AS/NZS 4284:2008 | Testing of building facades |
25 | SS381:1996 | Materials and performance tests for aluminum curtain walls |